Placement and repair of stainless steel reactor

During the maintenance of stainless steel reactor, attention should be paid to the working conditions of the whole equipment and reducer. In the process of use, the lubricating oil in the reducer needs to be supplemented. The electric heating medium oil in the stainless steel reactor needs to be replaced every half a year.
The electric heating rod, distillation hole, electrical instrument, pressure gauge and other components on the stainless steel reactor need to be inspected regularly. If there is any fault in the process of use, it needs to be adjusted or repaired. When the equipment is not in use, it needs to clean the inner and outer walls of the container with warm water.
In the process of using stainless steel reactor, the factors such as temperature change and mechanical collision often cause blowholes, cracks, bubbles, decarbonization and surface glaze, which can not appear in enamel equipment.
Once the above problems are found in the stainless steel reactor, it needs to be repaired in time. The polymer composite material is used to repair the stainless steel reactor on site. The repair agent is a two-component composite material with curing agent and polymer and ceramic powder as the base material.
In the process of using stainless steel reactor, compared with the ordinary resin repair agent, its polymer composite material mainly depends on its own fine polymer structure, which will make the material itself has strong adhesion and corrosion resistance.
Stainless steel reactors should be placed indoors. If there are multiple autoclaves in the room, they should be placed separately. Each operating room should have an outlet directly leading to the outdoor or passageway, so that the equipment ground point can be well ventilated.